Views:

Issue:

Starting with the 2021.1 Update of Graitec PowerPack for Autodesk Advance Steel, the user can encounter the above message when the “General” tab in the “General” category inside “Defaults” from Management Tools is accessed.

Error message

Error message

Solution:

To solve this issue, try the following solution:

1. Open Management Tools -> Table editor

Table editor

Table editor

 

2. Open installed databases -> AstorSettings

AstorSettings

AstorSettings

 

3. In the “Default_STR” table, modify the “TypeValue” of the “C0_GRTCNoMachiningAttributeValue” default, from “Yes-No-Field” to “Input box

“Default_STR” table

“Default_STR” table

 

4. In the “Default_STR_AdvanceSteel” table, modify the “TypeValue”  of the “C0_GRTCNoMachiningAttributeValue” default, from “1” to “0

“Default_STR_AdvanceSteel” table

“Default_STR_AdvanceSteel” table

 

5. In the “Default_STR_Original” table, modify the “TypeValue” of the “C0_GRTCNoMachiningAttributeValue” default, from “1” to “0

“Default_STR_Original” table

“Default_STR_Original” table

 

6. If there is an additional profile, modify the “TypeValue” of the “C0_GRTCNoMachiningAttributeValue” default, from “1” to “0” in the specific table.

Note: The “TypeValue” = 1 means “Yes-No-Field”, while “TypeValue” = 0 means “Input box”

After modifying the default, close Management Tools and use the “Update Defaults” option to update the database.

Status:

This incident has been reviewed. A resolution is being planned for a future release.

Related Products Graitec PowerPack for Advance Steel